Choosing the Right Fiber Connector: Comparing PC vs UPC vs APC Types

Choosing the Right Fiber Connector: Comparing PC vs UPC vs APC Types
Fiber Connector

What are the different types of fiber connectors?

——

There are three primary types of fiber connectors to consider: Physical Contact (PC), Ultra Physical Contact (UPC), and Angled Physical Contact (APC). PC connectors offer a good quality connection, are generally used in datacoms and telecoms, and have a more extensive back reflection than UPC and APC connectors. UPC connectors provide an extended version of the PC with a better surface finish, hence offering lower back review, which is crucial in digital and analog systems. Finally, APC connectors, with their 8-degree angled finish, ensure the most subordinate back consideration out of the three, making them ideal for high bandwidth applications and long-haul transmissions.

different types of fiber connectors
different types of fiber connectors

PC Fiber Connector

The Physical Contact (PC) fiber connector is a widely used type known for its physical contact in the ferrule design. The end faces of the fibers are typically polished to be slightly curved or spherical, allowing them to touch each other and minimizing back reflection. This design helps to achieve a good signal quality and reliable connection.

UPC Fiber Connector

The Ultra Physical Contact (UPC) fiber connector is an improved version of the PC connector. UPC connectors undergo an extended polishing process for a smoother and more domed end-face, resulting in a better optical performance. They offer lower back reflection than PC connectors, making them suitable for digital, telephony, and data applications.

APC Fiber Connector

The Angled Physical Contact (APC) fiber connector boasts the highest performance among these types. It features an 8-degree angled end face, reducing back reflection even more than UPC. This characteristic makes APC connectors ideal for high-bandwidth applications and long-haul transmissions.

Flat Fiber Connector

The Flat Fiber connector, as the name suggests, has a flat end-face. It was one of the earliest designs and does not provide as good a connection as PC, UPC, or APC due to the lack of physical contact between fiber ends. It’s less commonly used in modern applications.

Physical Contact Connector

The Physical Contact connector represents a broad category that includes both PC and UPC connectors. These connectors are designed so that the fiber ends physically contact each other, reducing signal loss and providing a reliable connection.

In conclusion, the selection between PC, UPC, APC, and Flat connectors primarily depends on your specific application requirements and the performance level you aim to achieve. Understanding these technical differences will guide you in making an informed choice.

What is the difference between PC, UPC, and APC connectors?

——

FactorPC (Physical Contact)UPC (Ultra Physical Contact)APC (Angled Physical Contact)
Polish TypeSlight curve at the end-face due to physical contact designExtended polish for a more domed end-face, enhancing optical performance8-degree angled end-face, providing the optimal connection
Back ReflectionDecent reduction in back reflectionFurther reduced back reflection due to smoother, more polished end-faceLowest back reflection due to angled end-face, ideal for high bandwidth and long-haul transmission applications
Fiber CladdingInteraction with end-face impacts performanceEnhanced interaction due to superior polishOptimal interaction due to angled end-face
Loss (Attenuation)Slightly higher loss compared to UPC and APCLower loss due to superior polishLeast loss, minimizing reflection and maximizing signal strength
Signal QualityProvides a robust and reliable connectionImproved signal quality due to enhanced polishHighest signal quality due to unique design that minimizes reflection

Difference in Polish Type

PC (Physical Contact), UPC (Ultra Physical Contact), and APC (Angled Physical Contact) connectors differ primarily in their polish type. PC connectors have a slight curve at the end face, while UPC connectors have an extended polish for a more domed end face, improving optical performance. APC connectors have an 8-degree angled end-face, providing the best connection among these types.

Difference in Back Reflection

Each connector type also offers varying levels of back reflection. PC connectors offer a decent reduction in back reflection due to their physical contact design, but UPC connectors take it a step further with a smoother, more polished end-face. APC connectors, with their angled end-face, provide the lowest back reflection, ideal for high bandwidth and long-haul transmission applications.

Differences in Fiber Cladding

The fiber cladding is consistent across PC, UPC, and APC connectors. What differentiates them is the way the cladding interacts with the connector end-face. The polish type on each connector (PC, UPC, and APC) affects how the cladding helps guide the light signal through the connector, impacting overall performance.

Difference in Loss

Loss, or attenuation, is another critical comparison point. PC connectors, while reliable, have slightly higher losses than UPC and APC. UPC connectors have a lower loss due to their superior polish, and APC connectors have a minor loss thanks to their angled end-face, minimizing reflection and maximizing signal strength.

Difference in Signal Quality

Signal quality is ultimately impacted by all the factors mentioned above. While PC connectors provide a robust and reliable connection, UPC and APC connectors offer improved signal quality. UPC’s enhanced polish results in a stronger signal, and APC’s unique design minimizes reflection to deliver the highest signal quality.

In conclusion, while all three types of connectors – PC, UPC, and APC – serve their purpose in different scenarios, understanding their technical differences can help you choose the right connector for your specific fiber optic HDMI cable needs.

Which connector type should I choose for my application?

——

Choosing the right connector type for fiber optic cables is an essential part of optimizing your network’s performance. There are several factors to consider when making this decision, and understanding the differences among connector types can help you make an informed choice.

Connector Types

The most common types of connectors technicians encounter are LC connectors, SC connectors, ST connectors, and MPO connectors1. Each of these has its specific use cases and advantages.

Determining the Best Connector Type

To determine the best connector type for your application, consider factors such as the mode (single mode or multimode), jacket materials, number of fibers, and the specific requirements of your network2. Each connector type is designed with particular applications in mind, so understanding your needs can guide you toward the right choice.

Fiber End Face Condition

The condition of the fiber end face is another critical factor in connector selection3. The end face condition can impact signal quality, loss, and back reflection. PC, UPC, and APC connectors differ in their polish type, which affects these factors4.

Recommendations for Optical Fiber Signaling

For optical fiber signaling, the choice of connector can significantly impact signal quality and reliability. UPC connectors, with their extended polish for a more domed end-face, offer improved optical performance. However, for high bandwidth and long-haul transmission applications, APC connectors, with their 8-degree angled end-face, provide the lowest back reflection and highest signal quality4.

Comparing PC vs. UPC vs. APC Connectors for Different Applications

PC, UPC, and APC connectors each have unique features that make them suitable for different applications4. PC connectors provide a robust and reliable connection, UPC connectors offer improved signal quality due to their enhanced polish, and APC connectors deliver the highest signal quality due to their unique design that minimizes reflection.

In conclusion, the choice of connector type for your fiber optic cables can significantly impact the performance of your network. Understanding the differences among these types and considering your specific application requirements will help you make the right choice.

Footnotes

  1. Jonard
  2. CablesToGo
  3. GoMultilink
  4. Optcore 2 3

Advantages and Disadvantages of PC, UPC, and APC Connectors

——

PC Connectors

Advantages of PC Connectors

Physical Contact (PC) connectors offer a robust and reliable connection. They are typically the most straightforward option for fiber optic connectors, making them easy to install and maintain. Additionally, they provide a good level of signal quality, suitable for a range of applications.

Disadvantages of PC Connectors

Despite their benefits, PC connectors may not provide the optimum level of signal quality required for specific high-performance applications. They also need regular cleaning to maintain performance and prevent damage.

UPC Connectors

Advantages of UPC Connectors

Ultra Physical Contact (UPC) connectors offer enhanced signal quality thanks to their extensive polish. This polish reduces back reflection, improving the effectiveness of signal transmission. UPC connectors also provide a more secure connection than PC connectors, reducing the likelihood of disconnections.

Disadvantages of UPC Connectors

UPC connectors may require more careful installation and maintenance due to their extensive polish. Furthermore, while they offer improved signal quality over PC connectors, they still may not meet the needs of specific high-bandwidth applications.

APC Connectors

Advantages of APC Connectors

Angled Physical Contact (APC) connectors deliver the highest signal quality of all three types thanks to their unique design that minimizes reflection. This makes them ideal for high-bandwidth, long-haul transmission applications where signal quality is paramount.

Disadvantages of APC Connectors

APC connectors can be more complex to install and maintain due to their angled end face. They also tend to be more expensive than PC and UPC connectors, which can be a consideration when budget is a factor.

Compatibility and Interchangeability of UPC and APC Connectors

——

While UPC and APC connectors are designed to serve similar purposes, they are not entirely interchangeable. The significant difference between these connector types is the angle of the connector end face – UPC connectors have a flat end face, while APC connectors have an angled end. The consequences of interchanging these connectors could lead to increased loss or even damage to the components.

UPC and APC Connectors
UPC and APC Connectors

When to Use UPC Connectors?

UPC connectors are a suitable choice when you require better return loss than PC connectors but don’t need the superior performance of an APC connector. They are ideal for digital, telephony, and data applications, where reflection is not a significant issue.

When to Use APC Connectors?

APC connectors should be used in applications where return loss is critical, such as in high-speed digital applications or analog systems. With their unique design, they offer the highest quality signal transmission, making them a popular choice for high-bandwidth, long-distance networks.

Advantages of Using Correct Connectors for Optimal Performance

Using the correct connectors in your network can ensure optimal performance, decrease potential issues, and lengthen the lifespan of your components. Selecting the appropriate connector for your application can reduce back reflection, improve connection security, and enhance signal transmission.

Potential Issues with Using Incorrect Connectors

Interchanging UPC and APC connectors or using the wrong connector for your application can lead to a host of issues. These may include increased loss, lower quality signal transmission, potential damage to your components, more frequent disconnections, and overall reduced network performance.

Frequently Asked Questions

——

Q: What are the different types of fiber connectors?

A: The three most common types of fiber connectors are PC (Physical Contact), UPC (Ultra Physical Contact), and APC (Angled Physical Contact).

Q: What is the difference between PC, UPC, and APC connectors?

A: The main difference lies in the polish style and the angle of the end face. PC connectors have a flat, non-angled end face, while UPC connectors have a slightly curved end face. APC connectors, on the other hand, have an angled end face at an 8-degree angle.

Q: When should I use APC connectors over UPC or PC connectors?

A: APC connectors are mainly used in applications where a high return loss is required, such as in telecommunications and long-haul networks. They are preferred for single-mode fiber connections.

Q: What are the advantages of APC connectors?

A: APC connectors provide a better connection quality due to their angled end face, reducing back reflection and increasing return loss. This ensures better signal transmission and minimizes the impact of reviews on the network.

Q: Can I use PC or UPC connectors with single-mode fiber?

A: Yes, PC and UPC connectors can be used with single-mode fiber, but APC connectors are generally preferred due to their superior back reflection performance.

Q: What are the advantages of UPC connectors?

A: UPC connectors offer superior performance compared to PC connectors. They have a higher return loss and provide better overall signal quality, making them suitable for both single-mode and multimode fiber applications.

Q: Can I use PC or APC connectors with multimode fiber?

A: Yes, PC and APC connectors can be used with multimode fiber, but UPC connectors are generally preferred due to their better overall performance.

Q: What is the difference in performance between APC and UPC connectors?

A: APC connectors provide better back reflection performance and lower loss compared to UPC connectors. This makes them more suitable for applications requiring high precision and low loss, such as fiber-to-the-home (FTTH) systems.

Q: Can I mix different types of connectors in a fiber optic network?

A: While it is technically possible to mix different types of connectors, it is generally not recommended. Mixing connectors can lead to increased signal loss and back reflection, resulting in degraded network performance.

Q: What type of connector should I choose for my fiber optic network?

A: The choice of connector depends on the specific requirements of your network. Consider factors such as the type of fiber (single-mode or multimode), the desired performance levels, and the application. Consulting with a fiber optic expert can help you determine the most suitable connector type for your needs.

References

  1. “Fiber Optic Connectors – The Complete Guide.” Beyondtech Inc, 2020. www.beyondtech.us/blog/fiber-optic-connectors-guide.
  2. “Understanding Fiber Polishing: PC, UPC, and APC.” FS, 2019. www.fs.com/blog/understanding-fiber-polishing-pc-upc-and-apc.html.
  3. “Choosing the Right Fiber Connector – PC, UPC or APC.” Precision Fiber Products, 2018. www.precisionfiberproducts.com/blog/choosing-the-right-fiber-connector-pc-upc-or-apc/.
  4. “Fiber Connector Types in Optical Communications: Overview, Evolution and Comparison.” FS, 2021. www.fs.com/blog/fiber-connector-types-overview-evolution-and-comparison.html.
Facebook
Twitter
Reddit
LinkedIn
Products From AscentOptics
Recently Posted
Contact AscentOptics
Contact Form Demo
Scroll to Top